Trap (plumbing)

Water seal in drain pipe under a sink. Water enters at right, fills the trap, and continues left. Inverted siphoning occurs below the line "A".
Examples of traps

In plumbing, a trap is a device which has a shape that uses a bending path to capture water to prevent sewer gases from entering buildings, while allowing waste to pass through. In oil refineries, traps are used to prevent hydrocarbons and other dangerous gases from escaping outside through drains.

In domestic applications, traps are typically U, S, Q, or J-shaped pipe located below or within a plumbing fixture. An S-shaped trap is also known as an S-bend. It was invented by Alexander Cummings in 1775 but became known as the U-bend following the introduction of the U-shaped trap by Thomas Crapper in 1880. The new U-bend could not jam, so, unlike the S-bend, it did not need an overflow. The most common of these traps in houses is referred to as a P-trap. It is the addition of a 90 degree fitting on the outlet side of a U-bend, thereby creating a P-like shape. It is also referred to as a sink trap because it is installed under most house sinks.

Because of its shape, the trap retains a small amount of water after the fixture's use. This water in the trap creates a seal that prevents sewer gas from passing from the drain pipes back into the occupied space of the building. Essentially all plumbing fixtures including sinks, bathtubs, and toilets must be equipped with either an internal or external trap.

Because it is a localized low-point in the plumbing, sink traps also tend to capture heavy objects (such as jewelry) that are inadvertently dropped into the sink. Traps also tend to collect hair, sand, and other debris and limit the ultimate size of objects that will pass on into the rest of the plumbing, thereby catching oversized objects. For all of these reasons, most traps can either be disassembled for cleaning or they provide some sort of cleanout feature.

When a large volume of water may be discharged through the trap, a standpipe may be required to prevent impact to other nearby traps.

History

An S-shaped trap is also known as an S-bend. It was invented by Alexander Cummings in 1775 but became known as the U-bend following the introduction of the U-shaped trap by Thomas Crapper in 1880. The new U-bend could not jam, so, unlike the S-bend, it did not need an overflow.

Once invented, in spite of being simple and reasonably reliable, widespread use in sewage was slow coming. In Britain, the plumbing needed to support the full use of traps was introduced only when the Thames, which was being used as an open sewer forced the legislators to pass laws in the 1860s to install closed sewers so as to avoid the unbearable smell reaching the nearby Houses of Parliament. As of 2017, only about two-thirds of the world population have access to traps, in spite of the evidence that good sewage systems significantly improve economic productivity in countries that employ them.[1]

Venting and auxiliary devices

Trap with copper drain pipe at underside of firestop packing in 2 hour fire-resistance rated concrete floor slab
Typical P-trap

Maintaining the water seal is critical to trap operation; traps can and do dry out, and poor venting can suction or blow water out of the traps. This is usually avoided by venting the drain pipes downstream of the trap; by being vented to the atmosphere outside the building, the drain lines never operate at a pressure much higher or lower than atmospheric pressure. Plumbing codes usually provide strict limitations on how far a trap may be located from the nearest vent stack.

When a vent cannot be provided, codes may allow the use of an air admittance valve instead. These devices avoid negative pressure in the drain pipe by venting room air into the drain pipe (behind the trap). A "Chicago Loop" is another alternative.

When a trap is installed on a fixture that is not routinely used, the eventual evaporation of the water in the trap must be considered. In these cases, a trap primer may be installed; these are devices that automatically recharge traps with water to maintain their water seals.

Accepted traps

In some regions of the United States, "S" traps are no longer accepted by the plumbing codes or are even illegal, as these traps tend to easily siphon dry even when well-vented. It is often possible to tell whether a household uses an S- or U-bend by checking for the presence of an overflow pipe outlet. What is required instead is a P-trap with proper venting. Certain drum-styled traps are also discouraged or banned.[2]

See also

Notes

  1. 50 Things That Made the Modern Economy: S-Bend
  2. Saltzman, Reuben (April 18, 2013). "How Bad Are Drum Traps?". The Home Inspector (blog). Star Tribune. Minneapolis. Archived from the original on July 15, 2015. Retrieved December 28, 2016. Includes several photographs of various types of drum traps.
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.