Well domains, can be set up using the following instructions, as outlined in Section 2.3.2.2 and in Equation 2.55. The variable radius corresponds to , while the pumping rates , use the new boundary condition format as described in Section 5.7.

Default Well Properties

Unless the user modifies the default values, all well zones in the domain will be assigned the default properties. The default values, Table 5.8, can be and are recommended to be modified to fit the model application.

Table 5.8: Default Values for Well Properties
ParameterValueUnit
Screen Radius1 × 10−5m
Coupled Conductivity7.438 × 10−5m s−1
Coupled Length1 × 10−4m
Well TypeHagen-Poiseuille-
Manning’s Friction Coefficient0.0548m−1/3 s
Hazen Williams Coefficient130m0.37 s−1


Example Well Instructions

As an example, the following set of instructions, with prefix.wprops file Figure 5.12, could be inserted into the prefix.grok file to produce a pumping well:

use domain type
well

properties file
prefix.wprops

clear chosen segments
choose segments polyline               !Screen interval
2
100. 100. 0.
100. 100. 20.

new zone
1

clear chosen zones
choose zone number
1

read properties
well one

clear chosen nodes
choose node                            !Bottom of pump intake
100. 100. 0.

create node set
well

boundary condition
    type
    flux nodal

    name
    well

    node set
    well

    time value table
    0.0 -80.0e-3                        !Pumping duration and rate
    end
end


The well domain example opens the property file prefix.wprops, shown in Figure 5.12, and creates a 20 m long screen located at x = 100 and y = 100 with a pump intake located at z = 0. The well one properties are read into grok and a steady pumping rate is set at -80 × 10−3 m3 s−1. If the flowrate is set to zero, the well is passive but can still transmit water vertically through its screen.

!------------------------------------------
well one

radius
0.05d0

coupling length
1.0e-4

coupling conductivity
.0023

end
Figure 5.12: Sample well domain property file prefix.wprops



Radius

Scope: .grok .wprops

  1. WellScreenRadius Well Screen Radius [L].

The radius of the screen interval of the well.



Infilled

Scope: .grok .wprops

  1. WellPropsInfilled Infilled well properties name from .mprops file.

This command should be included in the input file for an infilled well. The default values are a sand as described in Table 5.7.



Hagen Poiseuille

Scope: .grok .wprops

This command should be included in the input for the Hagen Poiseuille flow option.



Hazen Williams

Scope: .grok .wprops

This command should be included in the input file for the Hazen Williams flow option.



Manning

Scope: .grok .wprops

This command should be included in the input file for the Manning flow option.



Friction

Scope: .grok .wprops

  1. well_friction Manning’s Well Friction.


Hazen Williams coefficient

Scope: .grok .wprops

  1. well_hw_coeffient Hazen-Williams well coefficient.


Saturated wells

Scope: .grok .wprops

This instruction causes wells to remain fully saturated.



Dual nodes for wells

Scope: .grok .wprops

This instruction causes well flow scheme to use dual node approach.



Coupling conductivity

Scope: .grok .wprops

  1. WellPropsCplCond Coupling conductivity for well [L T−1].

Coupling conductivity parameter only required for the dual node approach for wells.



Coupling length

Scope: .grok .wprops

  1. WellPropsCplLngth Coupling length for well [L].

Coupling length parameter only required for the dual node approach for wells.